Reverse distal femoral locking plate for subtrochanter femur fracture

  • Peter Giarso Department of Orthopaedic and Traumatology, Faculty of Medicine Universitas Indonesia, Cipto Mangunkusumo Hospital, Jakarta
  • Ismail H. Dilogo Department of Orthopedic and Trautomatology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Jakarta
Keywords: subtrochanteric fracture, reverse distal femoral locking plate
Abstract viewed: 1368 times
PDF downloaded: 917 times
HTML downloaded: 345 times
EPUB downloaded: 161 times

Abstract

In these case series, we used titanium locking compression plate-distal femur (LCP-DF) plate (Synthes) 9–11 hole using less invasive stabilization system or open reduction technique. This case series aims to determine the functional scores on reverse distal femoral locking plate for subtrochanteric femur fracture. A 34-year-old male with closed subtrochanteric fracture of the right femur (Seinsheimer 2B) with Harris hip scores (HHS) of 17, 96, and 97 obtained consecutively in 0, 6, and 12 months, respectively. A 24-year-old male with closed comminuted subtrochanteric fracture of the right femur (Seinsheimer V) with HHS of 13, 93, and 97 at 0, 6, and 12 months respectively. A 39-year-old male with non-union, left subtrochanteric femur fracture (Seinsheimer 2C) yielded HHS of 38, 73, and 77 at 0, 6, and 12 months, respectively. A 35-year-old female with close subtrochanteric fracture of the right femur (Seinsheimer IIB) yielded HHS of 23, 40, and 73 at 0, 6, and 12 months, respectively. Mean initial HHS and scores at 6 and 12 months reached 22, 75, and 86, respectively.

References

  1. Baumgaertner MR, Oetgen ME. Intertrochanteric Hip Fractures. In: Browner BD. Skeletal Trauma: basic science, management, and reconstruction. Philadelphia: Sanders; 2003.

  2. Hoffmann R, Han NP. Femur: Proximal. In: Ruedl TP, Murphy WM. AO Principles of Fracture Management. New York: Thieme; 2000. p. 441-5.

  3. Beaty JH, Austin SM, Warner WC, Canale ST, Nichols L. Interlocking intramedullary nailing of femoral-shaft fractures in adolescents: preliminary results and complications. J Pediatr Orthop Relat Res. 1994;14(2):178-83. https://doi.org/10.1097/01241398-199403000-00009

  4. Wolfgang GL, Bryant MH, O'Neill JP. Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop. 1982;(163):148-58. https://doi.org/10.1097/00003086-198203000-00022

  5. Bain GI, Zacest AC, Paterson DC, Middleton J, Pohl AP. Abduction strength following intramedullary nailing of the femur. J Orthop Trauma. 1997;11(2):93-7. https://doi.org/10.1097/00005131-199702000-00004

  6. Dodenhoff RM, Dainton JN, Hutchins PM. Proximal thigh pain after femoral nailing: causes and treatment. J Bone Joint Surg Br. 1997;79(5):738-41. https://doi.org/10.1302/0301-620X.79B5.7345

  7. Dora C, Leunig M, Beck M, Rothenfluh D, Ganz R. Entry point soft tissue damage in antegrade femoral nailing: a cadaver study. J Orthop Trauma. 2001;15(7):488-93. https://doi.org/10.1097/00005131-200109000-00005

  8. Zhang CQ, Sun Y, Jin DX, Yao C, Chen SB, Zeng BF. Reverse LISS plating for intertrochanteric hip fractures in elderly patients. BMC Musculoskelet Disord. 2010;11:166. https://doi.org/10.1186/1471-2474-11-166

  9. Haidukewych GJ, Ricci W. Locked plating in orthopaedic trauma: a clinical update. J Am Acad Orthop Surg. 2008;16(6):347-55. https://doi.org/10.5435/00124635-200806000-00007

  10. Sidhom SA, Pinder R, Shaw DL. Reverse LISS plate stabilisation of a subtrochanteric fracture of the femur in a patient with osteopetrosis: is this the answer? Injury Extra. 2006;37:113-5. https://doi.org/10.1016/j.injury.2005.09.022

  11. Ma CH, Tu YK, Yu SW, Yen CY, Yeh JH, Wu CH. Reverse LISS plates for unstable proximal femoral fractures. Injury. 2010;41(8):827-33. https://doi.org/10.1016/j.injury.2010.03.028

  12. Acklin YP, Bereiter H, Sommer C. Reversed LISS-DF in selected cases of complex proximal femur fractures. Injury. 2010;41(4):427-9. https://doi.org/10.1016/j.injury.2009.05.033

  13. Ehlinger M, Brinkert D, Besse J, Adam P, Arlettaz Y, Bonnomet F. Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation. Orthop Traumatol Surg Res. 2011;97(5):560-4. https://doi.org/10.1016/j.otsr.2010.12.007

  14. Haq RU, Manhas V, Pankaj A, Srivastava A, Dhammi IK, Jain AK. Proximal femoral nails compared with reverse distal femoral locking plates in intertrochanteric fractures with a compromised lateral wall; a randomised controlled trial. Int Orthop. 2014;38(7):1443-9. https://doi.org/10.1007/s00264-014-2306-1

Published
2018-09-09
How to Cite
1.
Giarso P, Dilogo IH. Reverse distal femoral locking plate for subtrochanter femur fracture. Med J Indones [Internet]. 2018Sep.9 [cited 2024Apr.19];27(2):121–7. Available from: http://mji.ui.ac.id/journal/index.php/mji/article/view/1377
Section
Case Report/Series