A case series of eight scoliosis patients undergone pedicle screw placement with freehand technique: study for safety and accuracy

Authors

  • Komang Agung Irianto Department of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Airlangga, Dr. Soetomo Hospital, Surabaya, Indonesia
  • Marquee Kenny Tumbelaka Department of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Airlangga, Dr. Soetomo Hospital, Surabaya, Indonesia

DOI:

https://doi.org/10.13181/mji.cr.191978

Keywords:

pedicle screws, scoliosis
Abstract viewed: 689 times
PDF downloaded: 710 times
HTML downloaded: 78 times
EPUB downloaded: 171 times

Abstract

BACKGROUND Pedicle screws and rods are routinely inserted in the vertebrae thoracic to lumbar in scoliosis reconstruction surgery to gain deformity correction and fusion. Intraoperative imaging is often needed to ensure accuracy, but surgical time will be longer and there will be more radiation exposure. Meanwhile, freehand technique is accepted as safe. This study was aimed to evaluate the accuracy of screw insertion in the freehand technique used in adolescent scoliosis surgery.

METHODS This case series evaluated a total of 127 pedicle screws inserted using the freehand technique in 8 out of 28 adolescent scoliosis patients from 2011 to 2016 whom agreed for computed tomography (CT) scan follow-up from 2011 to 2016 in Dr. Seotomo Hospital, Surabaya. The accuracy and safety of the freehand technique were evaluated postoperatively in each patient using a CT scan. A successful screw was considered accurate if it was within the vertebral body and inside the safety zone (within the limit of 2–4 mm to the medial or lateral side of the vertebral body.

RESULTS Of the 127 screws inserted, 106 (83.5%) were accurately placed, and 110 (86.6%) were within the safe zone. According to the level of the spine, in the upper and middle thoracic spine, the inserted screws were accurate in 69.4% and 74.9% within the safety zone, whereas in the lower thoracic and lumbar spine, 94.0% and 95.0% within the safety zone.

CONCLUSIONS The freehand technique in scoliosis reconstructive surgery performed by experienced surgeons is accurate and safe. 

Downloads

Download data is not yet available.

References

Tian NF, Huang QS, Zhou P, Zhou Y, Wu RK, Lou Y, et al. Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J. 2011;20(6):846-59. https://doi.org/10.1007/s00586-010-1577-5

Vijayeswaran N, Venkatesh R, Murugesan G, Balamurugan S, Indunesh K, Pradeep TT. Is freehand technique of pedicle screw insertion in thoracolumbal spine safe and accurate? Assessment of 250 screws. J Neurosci Rural Pract. 2019;10(2):256-60. https://doi.org/10.4103/jnrp.jnrp_183_18

Olsewski JM, Simmons EH, Kallen FC, Mendel FC, Severin, CM, Berens DL. Morphometry of the lumbar spine: anatomical perspectives related to transpedicular fixation. J Bone Joint Surg Am. 1990;72(4):541-9. https://doi.org/10.2106/00004623-199072040-00011

Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, et al. Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. J Bone Joint Surg Am. 1995;77(8):1200-6. https://doi.org/10.2106/00004623-199508000-00009

Su P, Zhang W, Peng Y, Liang A, Du K, Huang D. Use of computed tomographic reconstruction to establish the ideal entry point for pedicle screws in idiopathic scoliosis. Eur Spine J. 2012;21(1):23-30. https://doi.org/10.1007/s00586-011-1962-8

Rivkin MA, Okun JF, Yocom SS. Novel free-hand T1 pedicle screw method: review of 44 consecutive cases. J Neurosci Rural Pract. 2014;5(4):349-54. https://doi.org/10.4103/0976-3147.139974

Oh CH, Yoon SH, Kim YJ, Hyun D, Park HC. Technical report of free hand pedicle screw placement using the entry points with junction of proximal edge of transverse process and lamina in lumbar spine: analysis of 2601 consecutive screws. Korean J Spine. 2013;10(1):7-13. https://doi.org/10.14245/kjs.2013.10.1.7

Li J, Zhao H, Xie H, Yu L, Wei J, Zong M, et al. A new free-hand pedicle screw placement technique with reference to the supraspinatus ligament. J Biomed Res. 2014;28(1):64-70. https://doi.org/10.7555/JBR.27.20130051

Chan A, Parent E, Narvacan K, San C, Lou E. Intraoperative image guidance compared with free-hand methods in adolescent idiopathic scoliosis posterior spinal surgery: a systematic review on screw-related complications and breach rates. Spine J. 2017;17(9):1215-29. https://doi.org/10.1016/j.spinee.2017.04.001

Avila MJ, Baaj AA. Freehand thoracic pedicle screw placement: review of existing strategies and step by step guide using uniform landmark for all levels. Cureus. 2016;8(2):e501. https://doi.org/10.7759/cureus.501

Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand. Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine. 2006;31(17):2024-7. https://doi.org/10.1097/01.brs.0000229250.69369.ac

Mason A, Paulsen R, Babuska JM, Rajpal S, Burneikiene S, Nelson EL, et al. The accuracy of pedicle screw placement using intraoperative image guidance systems. J Neurosurg Spine. 2014;20(2):196-203. https://doi.org/10.3171/2013.11.SPINE13413

de Marco FA, Risso-Neto MI, Cavali PTM, Sussi MA, Pasqualini W, Landim E. Placement analysis of thoracic and lumbar pedicle screws inserted under anatomic and radioscopic parameters. Columna. 2008;7:1-7.

Parker SL, Amin AG, Santiago-Dieppa D, Liauw JA, Bydon A, Sciubba DM, et.al. Incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Spine. 2014;39(8):683-7. https://doi.org/10.1097/BRS.0000000000000221

Suess O, Schomacher M. Control of pedicle screw placement with an electrical conductivity measurement device: initial evaluation in the thoracic and lumbar spine. Adv Med. 2016;2016:4296294. https://doi.org/10.1155/2016/4296294

Published

2020-07-01

How to Cite

1.
Irianto KA, Tumbelaka MK. A case series of eight scoliosis patients undergone pedicle screw placement with freehand technique: study for safety and accuracy. Med J Indones [Internet]. 2020Jul.1 [cited 2024Dec.24];29(2):222-7. Available from: http://mji.ui.ac.id/journal/index.php/mji/article/view/1978

Issue

Section

Case Report/Series
Abstract viewed = 689 times
PDF downloaded = 710 times HTML downloaded = 78 times EPUB downloaded = 171 times